This boiler is a highly efficient heat generator (efficiency of at least 91%) for heating and hot water supply, running both on natural and liquefied gas. The boiler is equipped with an atmospheric burner with an electronic system of ignition and microprocess or control system. The boiler can be placed indoors or outdoors, in a partially sheltered place, with an ambient temperature to -5 ° C.
The boiler has a digital control panel with the ability to indicate and control of the operating modes of heating and hot water supply, as well as an indication of burner operation. Besides the manual adjusting of water temperature in the boiler it is also possible to adjust the room temperature with the help of a room thermostat (optional), remote control (optional), and weather dependent automatics (when installing the outdoor temperature sensor). Also, by using the control panel it is possible to select "Summer/Winter" and "ECO/COMFORT"operating modes of the boiler, which enable or disable the constant heating of water in the hot water supply.
With the help of Configuration menu of control panel, it is possible to adjust the operation of the boiler by parameters such as type of gas, type of the boiler, type of combustion chamber, etc.
The tools menu of control panel consists of three submenus "TS", "In","Hi".
"TS" – Basic parameters of input menu. Allows to install and customize all the main settings of the boiler operation to prepare it for launch and further activity.
"In" – Information menu. Allows to visualize the data on the main operating parameters of the boiler.
"Hi" – History Menu.Allows to browse the fault history of the boiler (the last 10 faults).
Boilers are available in two versions - with a closed (model MCS) and open (Model MC) combustion chamber.
Description:
Compact size (less than 18% in comparison with analogues)
Inbuilt weather dependent automatics
Copper main and plate heat exchanger for hot water supply
Continuous electronically adjustable flame modulation in the contours of heating and hot water supply
Burner made from stainless steel
Regulation of smooth start-up (protection from cotton)
Temperature control range 31... 85 ° C
Possibility of using anti-freeze
Automatic by-pass
Protection system against pump blockage
LCD display
Self-diagnostics
3-speed circulator with function of post-circulation
Frost protection kit for setting the boiler outdoors in a partially protected place (optional)
Post-circulation of pump
Post-circulation of ventilation
Expansion tank of heating system
Minimum gas pressure in gas supply network 5 mbar
Adjustment and setting of gaz.valve fully in electronic mode
MC / IT – models with an open combustion chamber and natural draft.
MCS / IT - models with a closed combustion chamber and forced draft.
Technical Specifications
Weight, kg |
28 |
Dimensions, mm |
420х700х320 |
Maximum useful heat output, kW |
23.5 |
Minimum useful heat output, kW |
7 |